<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-07 18-59-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 71 kHz 3127 0,1599
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,42 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 11 kHz % above 76 kHz: 0,1599 Acquired: 2024/12/07 18.58.49 Total samples: 3127 Equivalent time: 0:02:36 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 6,3 dBr MIN: 4,7 dBr AVE: 5,42 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2024/12/07 18.58.49) 18.44 18.46 18.48 18.50 18.52 18.54 18.56 18.58 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]